Features  |  How to Use  |  FAQ  |  Ordering Information  |  Downloads
Font Size: Larger


Frequently Asked Questions

How often do I need to clean the analyzer?

What size is the paper roll and where can I buy it?

How much memory capacity does the DiaScreen 50 have?

How many tests many tests can the DiaScreen 50 run per hour?®?

Can I use lower multiple test strips in the same tray as the higher multiple test strips??

Can I use any brand test strip in the DiaScreen 50 Analyzer?

Do I have to blot the test strip before I put it on the tray to analyze?

Can I use a barcode reader or a keyboard to enter patient identification?

Does the DiaScreen 50 flag positive results?

Can I print more than 1 copy of the test results?

Do I have to use a sepatate calibration strip prior to using the DiaScreen 50?

Is the DiaScreen 50 CLIA waived?

Q: How often do I need to clean the analyzer?

A: The DiaScreen 50 Urine Chemistry Analyzer should be cleaned on a daily basis. At the end of the day, simply wipe down the test strip tray with a Kimwipe or cotton swab and distilled water. To thoroughly clean and disinfect the test strip tray, you may use Isopropul alcohol (70-85%) or household bleach - dilute 1 ml of 5% sodium hypochlorite solution in 99 ml of water to acchieve 1:100 diluiton (.05% sodium hypochlorite solution)

Q: What size is the paper role and where can I buy it?

A: You may buy thermal calculator rolls of paper size 2¼ x 85" at most office supply stores.

Q: How much memory capacity does the DiaScreen 50 have?

A: The DiaScreen 50 Analyzer has a memory capacity of the most recent 200 test results.

Q: How many tests can the DiaScreen 50 run in an hour?

A: The DiaScreen 50 has a throughput of 50 tests per hour.

Q: Can I use lower multiple test strips in the same tray as higher multiple test strips in the DiaScreen 50?

A: Yes. You may use the same tray for the lower multiple DiaScreen Reagent Strips for Urinalysis that have 3 or more analytes per strip as long as you make sure the strip is positioned so that the front end of the test strip is fully inserted against the front edge of the strip tray.

Q: Can I use any brand of test strip in the DiaScreen 50 Analyzer?

A: No. You must use DiaScreen Reagent Strips for Urinalysis with the DiaScreen 50 Analyzer.

Q: Do I have to blot the test strip before I put it on the tray to analyze?

A: Yes. Correct procedure will help ensure accurate test results. Blot the long edge of the test strip for one second before placing it on the test strip tray.

Q: Can I use a barcode reader or a keyboard to enter patient identificaiton?

A: Yes.

Q: Does the DiaScreen 50 flag positive results?

A: Yes. the DiaScreen 50 flags positive results with an asterisk.

Q: Can I print more than 1 copy of the test results?

A: Yes. You may set the analyzer to print 2 copies of test results.

Q: Do I have to use a separate calibration strip prior to using the DiaScreen 50?

A: No. The DiaScreen 50 self calibrates before each test. It is not necessary to use the separate calibration strip.

Q: Is the DiaScreen 50 CLIA waived?

A: Yes.

The DiaScreen 50 Urine Chemistry Analyzer is designed for use with the DiaScreen Reagent Strips for Urinalysis. It saves time for technicians, offering greater efficiency. The DiaScreen 50 virtually eliminates transcription errors with an easy-to-read printout and results are downloadable to a comupter. It minimizes variability between operators. Patient identification may be entered with the standard keypad or with a barcode reader or keyboard. The DiaScreen 50 may be used with DiaScreen Reagent Strips for Urinalysis with 3 or more analytes per strip.

 